Natural Decay Resistance of Glued-Laminated Beams
The natural decay resistance of untreated Douglas-fir heartwood specimens sampled from glued-laminated beams was evaluated using a modified agar plate test modeled after the European Standard...

Externally Stiffened I-Beam to Box-Column Connections
This paper is concerned with I-beam to Box-column connections stiffened externally. Experimental and theoretical findings on full-scale connection models are highlighted. The performance...

Creep Analysis of Composite Steel-Concrete Members with Deformable Connectors
The long-term analysis of composite steel-concrete beams with elastically deformable connectors is presented. The basic integro-differential equation governing the problem is solved by...

ATLSS Connections with Moment Capacity
ATLSS Connections are a family of beam-to-column connections which utilize the self-aligning feature of a specially designed connector and are developed for possible use in an automated...

Shear Design Guidelines for Polyester Concrete Using Recycled Plastic
Previous research on the shear behavior of steel-reinforced polymer concrete (PC) beams has been very limited and no efficient design procedures have been proposed. In all the previous...

Dynamic Response of Steel Fiber Reinforced Concrete
Extensive research has been done on the static properties of steel fiber reinforced concrete, but very little on the dynamic properties. A total of 20 beams was tested. The steel fiber...

Fracture Analysis of Bolted Timber Connections
Application of fracture mechanics concepts to splice connections where bolts load timber members perpendicular to the grain is discussed. Attention is given to prediction of the load level...

Validation of the European Yield Model for Nailed Connections
Recent changes in National Design Specification for Wood Construction (NDS) connection design methods make it necessary to validate the European yield model (EYM) for nails. Test values...

Special Considerations in the Design of Connections for Recycled Wood/Plastic Composite Lumber
There is current work in the American Society for Testing and Materials (ASTM) to evaluate potential test methods for what they refer to as 'commingled' plastic lumber. This category covers...

Low Strain Dynamic Testing of Wood Piles Supporting an Existing Pier
This paper presents a case history where low strain dynamic testing was performed to test wood piles supporting an existing structure. Under consideration is a 183 m long wooden pier constructed...

Timber Pile Length Determination Using a Nondestructive Technique
Determining timber pile length is critical when evaluating the potential effects of scour and for determining pile capacity. Unfortunately, records of timber pile lengths are typically...

Cyclical Behavior of Welded Steel Shear Studs
Four specimens of composite steel and concrete beams were experimentally tested to obtain the cyclical behavior of the welded steel shear stud. This information may be used for the analysis...

Time-Dependent Load-Distribution Behavior of Parallel-Member Wood Systems
The effect of differential member creep on the load-distribution behavior of parallel-member wood systems is examined. Variability in the creep response of the individual component members...

Cyclic Behavior of Joints Between Steel Beams and Reinforced Concrete Columns
The design and behavior of composite beam-column joints for seismic design are reviewed based on the results of tests. Issues addressed include the strength, deformation, and toughness...

Rigid Beam-To-Column Connection Detail for Circular Composite Columns
Steel pipes with relatively thin wall thickness and filled with high strength concrete have been used in building construction. Some of the advantages of this type of column include eliminating...

Aesthetic Issues in Timber Bridges
The vocabulary of visual design and several generally accepted major principles of visual design are reviewed in order to provide a 'context' for case studies of award-winning timber bridges....

Development of Hardwood Glulam Timber Bridge Standards
Design standards and specification for 5.5 to 27.4 m(18 to 90 ft.) clear span hardwood glued laminated (glulam) highway bridges have been developed and are available from the Pennsylvania...

Design and Field Performance of a Metal-Plate-Connected Wood Truss Bridge
This paper describes an on-going study on the design and performance attributes of an experimental wood-truss bridge. This is believed to be the first roadway bridge application of metal-plate-connected...

Bulb-T and Glulam-FRP Beams for Timber Bridges
In this paper, we discusses the manufacturing, analysis, and testing of two glulam beam designers:(1) Southern pine bulb, and (2) yellow-poplar reinforced with pultruded fiber-reinforced...

Acoustic Emission Monitoring of Fatigue Crack Growth in HSLA-80 Steel Box Beams
An acoustic emission is a transient elastic wave generated by the rapid release of energy from a localized source within a material. There can be many sources of acoustic emission in a...

 

 

 

 

Return to search